EC Sense TB420 / 4–20 mA Smart Gas Transmitter Modules

TB420 4–20 mA Smart Gas Transmitter Modules

Two-wire 4–20 mA smart gas transmitter modules covering 25 gas types across 47 models. A 45 × 35 mm board carries the electrochemical head itself, so two wires are all it takes to reach a PLC, DCS or data logger: a standard 4–20 mA current loop plus a fault output. Supply is 9 – 24 V DC with total consumption under 0.6 W and a loop current of 3 – 22 mA. Beyond mainstream industrial toxic gases this line also covers the semiconductor specialty gases silane (SiH₄), diborane (B₂H₆) and germane (GeH₄) — the only modules in the EC Sense catalogue that offer these three hydrides.

  • 25 Gas Types Covered
  • 47 Product Models
  • 4–20 mA Two-Wire Output
  • 9 – 24 V Supply (24 V recommended)
  • > 5 yr Expected Lifetime

Why Use a 4–20 mA Module Instead of a Digital Module Plus a Converter?

Digital modules (UART / I²C) suit teams building their own instrument: data goes straight into the host controller and temperature and humidity come along for free. But when the goal is simply to feed a gas concentration into one analog input channel on a PLC or DCS, a digital module needs an extra converter board, another protocol implementation and a second pass at power and isolation. The TB420 puts the electrochemical head, amplification, compensation and the 4–20 mA driver on one 45 × 35 mm board — two wires into the cabinet and you are done.

Why Use a 4–20 mA Module Instead of a Digital Module Plus a Converter?
Aspect Digital Module + Own ConverterTB420 Transmitter Module
Output Signal UART or I²C, requiring an MCU to convert to an analog or bus signalTwo-wire 4–20 mA standard current loop, with a fault output
PLC / DCS Integration Needs a custom converter board, protocol firmware and isolation designWired straight to an analog input: 4 mA at zero, 20 mA at full scale
Supply & Loop 3.3 – 5.5 V logic supply; long digital runs need extra interference planning9 – 24 V DC supply (24 V recommended), loop current 3 – 22 mA, under 0.6 W
Open-Circuit & Fault Diagnosis Heartbeat and timeout logic must be implemented in firmwareAnything below 4 mA reads as an open circuit or fault, plus a dedicated fault output
Mechanics & Mounting Board, head and converter board — footprint and routing to be planned from scratch45 × 35 × 21.7 mm including the head, 11.8 g, all on one board
Best For Teams building their own instrument who need temperature and humidity, custom algorithms and the lowest cost per pointEngineering projects adding gas points to an existing PLC or DCS, scaling channel by channel

Selection Guide

Five Steps to the Right Model

The TB420 spans 25 gas types, 47 models and 118 order numbers, and most gases come in several ranges with two cell options. Working through the sequence below usually settles the choice in one pass.

  1. Step 1 — Identify the target gas and the background gases

    Decide what you are measuring, then what else is present on site. This matters most with semiconductor specialty gases: the official cross-sensitivity table shows 100 ppm hydrogen reading about 20 ppm on the silane channel (roughly 20% positive interference), while 1 ppm chlorine reads negative (about −0.5 ppm). Where co-existing hydrogen or chlorine is likely, subtract at system level or split hydrogen and silane into separate channels.

  2. Step 2 — Size the range from your alarm setpoint

    Wider ranges mean coarser resolution, which is the easiest thing to overlook on a two-wire transmitter. A practical rule: pick a range two to five times your alarm setpoint. For H₂S, where occupational limits sit around 10 ppm, 0 – 100 ppm is enough; for silane, with an ACGIH limit of 5 ppm, the 0 – 10 ppm span at 0.001 ppm resolution covers leak confirmation comfortably. Every span for every gas appears in the matrix below.

  3. Step 3 — Choose the cell: ES1, ES4 or EC4

    This line also offers three cell options. ES1 and ES4 are solid-polymer electrochemical cells with the widest choice of spans, covering silane, diborane, germane and almost everything else; EC4 is a liquid-electrochemical cell dedicated to corrosive gases such as bromine, fluorine, hydrogen chloride and hydrogen fluoride. All three specialty gases sit on ES1/ES4 — there is no EC4 version. Note that EC4 has a shorter life than the solid-polymer cells, so factor the replacement interval into the decision.

  4. Step 4 — Check the two-wire wiring and supply

    The TB420 is two-wire: supply and signal share the same pair, with the module itself in the loop. Supply is 9 – 24 V DC (24 V recommended), loop current 3 – 22 mA and total consumption under 0.6 W. On a PLC analog input channel, scale 4 mA to the bottom of the range and 20 mA to the top; a reading below 4 mA means an open circuit or a fault, and a dedicated fault output pin is available for alarm logic. Choosing 24 V buys longer cable runs and more loop headroom.

  5. Step 5 — Check fit, environment and compliance

    The module measures 45 × 35 × 21.7 mm including the head (11.9 mm thick without it) and weighs 11.8 g, packed in a 120 × 150 mm ESD bag. Accuracy is ±5% of the measured value, repeatability better than 2%, expected lifetime beyond 5 years, and the sensor carries a lifetime self-test. Confirm the site stays within the datasheet's temperature, humidity and pressure limits, and whether your project needs RoHS or similar documents — certification status is stated in each model's datasheet, and we can supply the reports we hold. Warranty is 12 months from the date of shipment.

Choose the Output First: 4–20 mA vs 0–10 V vs Digital

Pick the wrong output for a measuring point and the wiring, diagnostics and future expansion all become awkward. The table below sets the three common options side by side — the 4–20 mA column reflects this module's published specifications, while the other two describe industry practice for comparison.

Choose the Output First: 4–20 mA vs 0–10 V vs Digital
Specification 4–20 mA Two-Wire (TB420)0–10 V Three-WireDigital UART / I²C
Transmission Distance Hundreds of metres; a current loop is insensitive to cable resistanceTens of metres; voltage drop across the cable shifts the readingShort runs inside a device or cabinet; long runs need extra hardening
Interference Immunity Strong — the current loop is the norm on petrochemical sites and around VFDsModerate — sensitive to EMI and common-mode voltageWeak — needs shielding, isolation and shorter runs
Open-Circuit Diagnosis Inherent: below 4 mA means open circuit or fault, plus a dedicated fault output pinHard to distinguish a true zero from an open circuitNeeds a protocol-level heartbeat or timeout
Supply & Consumption 9 – 24 V DC (24 V recommended), 3 – 22 mA loop, under 0.6 WTypically 12 – 24 V DC, consumption varying with load3.3 – 5.5 V DC, compatible with battery and IoT-node power
Resolution & Data Richness Limited by the 4–20 mA span and ADC bits; carries concentration onlyLimited by span and ADC bits; also carries concentration onlyResolution set by the protocol; can return concentration, temperature, humidity and self-check data together
Typical Applications Fixed points in cabinets, pipe racks and plant boundaries feeding a PLC or DCS over distanceShort runs, in-device mounting, or cost-sensitive designsCustom instruments needing temperature and humidity, custom algorithms or battery power

The 0–10 V and digital columns describe industry practice and are not specifications of our products. Figures for the TB420 itself are taken from the official TB420-ES1 / ES4 / EC4 datasheets (V2.0). The digital route is covered on this site by the TB200B and TB600B&C series, which can be compared on their series pages.

TB420 or TB200B / TB600B&C — Which One?

All three series use the same generation of EC Sense electrochemical technology with comparable gas readings; they differ in output and form factor. One question settles it: does this measuring point feed a PLC cabinet directly, or a host controller inside an instrument you are building?

Two-wire current loop · 25 gas types · includes semiconductor specialty gases

TB420 4–20 mA Transmitter Module

  • 25 gas types, 47 models and 118 order numbers — the longest gas list of the three series
  • The only module line offering silane (SiH₄), diborane (B₂H₆) and germane (GeH₄)
  • Two-wire 4–20 mA with fault output, 9 – 24 V DC, 3 – 22 mA loop, under 0.6 W
  • 45 × 35 × 21.7 mm with the head, 11.8 g, integrated on one board

Best for: engineering projects adding points to an existing PLC or DCS; petrochemical, water-treatment and semiconductor plants with long cable runs and strong EMI; and silane, diborane and germane leak monitoring.

UART or I²C · Board form factor · temp/RH included

TB200B / TB600B&C Digital Modules

  • Both UART (TTL 3.3 V) and I²C versions — data goes straight to an MCU with no analog conversion
  • Returns concentration plus ambient temperature and humidity, suiting compensation algorithms and local displays
  • 3.3 – 5.5 V DC supply; the TB600B&C draws 12.5 mW at 5 V and can run on batteries
  • Gas list focused on mainstream industrial toxic gases, without silane, diborane or germane

Best for: custom instruments and portable devices needing temperature, humidity and custom algorithms; battery-powered and IoT nodes; and sites where the head must reach inside cabinets and pipe racks on a cable.

If the point ends up on a 4–20 mA channel of a PLC, the TB420 is the shortest path. If you are building a product to sell, or need temperature, humidity and custom algorithms, choose a TB200B / TB600B&C digital module. The two often coexist in one system: distant field points over 4–20 mA, in-device points over a digital interface. If you are unsure, send us the system architecture.

Full Gas Coverage and Ranges

25 gas types across 47 models, with resolution down to 0.001 ppm and ranges up to 5,000 ppm and 25% vol. Click any model to open its detail page and download the datasheet.

Complete Order Number List

All 118 order numbers grouped by target gas. Use the filters below to narrow down by gas and Cell.

Shown: 118 / 118
Complete order number list
Target Gas Model Range Cell Order No. Datasheet
Arsine TB420-ES1-AsH3 0 – 1 ppm ES1 04-TB420-ES1-AsH3-1-01 PDF
Arsine TB420-ES4-AsH3 0 – 1 ppm ES4 04-TB420-ES4-AsH3-1-01 PDF
Diborane TB420-ES1-B2H6 0 – 1 ppm ES1 04-TB420-ES1-B2H6-1-01 PDF
Diborane TB420-ES4-B2H6 0 – 1 ppm ES4 04-TB420-ES4-B2H6-1-01 PDF
Bromine TB420-EC4-Br2 0 – 1 ppm EC4 04-TB420-EC4-Br2-1-01 PDF
Methyl Mercaptan TB420-ES1-CH4S 0 – 10 ppm ES1 04-TB420-ES1-CH4S-10-01 PDF
Methyl Mercaptan TB420-ES1-CH4S 0 – 100 ppm ES1 04-TB420-ES1-CH4S-100-01 PDF
Methyl Mercaptan TB420-ES1-CH4S 0 – 5000 ppm ES1 04-TB420-ES1-CH4S-5000-01 PDF
Methyl Mercaptan TB420-ES4-CH4S 0 – 10 ppm ES4 04-TB420-ES4-CH4S-10-01 PDF
Methyl Mercaptan TB420-ES4-CH4S 0 – 100 ppm ES4 04-TB420-ES4-CH4S-100-01 PDF
Methyl Mercaptan TB420-ES4-CH4S 0 – 5000 ppm ES4 04-TB420-ES4-CH4S-5000-01 PDF
Carbon Monoxide TB420-ES1-CO 0 – 10 ppm ES1 04-TB420-ES1-CO-10-01 PDF
Carbon Monoxide TB420-ES1-CO 0 – 100 ppm ES1 04-TB420-ES1-CO-100-01 PDF
Carbon Monoxide TB420-ES1-CO 0 – 1000 ppm ES1 04-TB420-ES1-CO-1000-01 PDF
Carbon Monoxide TB420-ES1-CO 0 – 2 % vol. ES1 04-TB420-ES1-CO-2%-01 PDF
Carbon Monoxide TB420-ES4-CO 0 – 10 ppm ES4 04-TB420-ES4-CO-10-01 PDF
Carbon Monoxide TB420-ES4-CO 0 – 100 ppm ES4 04-TB420-ES4-CO-100-01 PDF
Carbon Monoxide TB420-ES4-CO 0 – 1000 ppm ES4 04-TB420-ES4-CO-1000-01 PDF
Carbon Monoxide TB420-ES4-CO 0 – 2 % vol. ES4 04-TB420-ES4-CO-2%-01 PDF
Chlorine TB420-EC4-Cl2 0 – 5 ppm EC4 04-TB420-EC4-Cl2-5-01 PDF
Chlorine TB420-EC4-Cl2 0 – 50 ppm EC4 04-TB420-EC4-Cl2-50-01 PDF
Chlorine TB420-ES1-Cl2 0 – 100 ppm ES1 04-TB420-ES1-Cl2-100-01 PDF
Chlorine TB420-ES4-Cl2 0 – 100 ppm ES4 04-TB420-ES4-Cl2-100-01 PDF
Chlorine Dioxide TB420-EC4-ClO2 0 – 5 ppm EC4 04-TB420-EC4-ClO2-5-01 PDF
Ethylene Oxide TB420-ES1-ETO 0 – 10 ppm ES1 04-TB420-ES1-ETO-10-01 PDF
Ethylene Oxide TB420-ES1-ETO 0 – 200 ppm ES1 04-TB420-ES1-ETO-200-01 PDF
Ethylene Oxide TB420-ES1-ETO 0 – 1000 ppm ES1 04-TB420-ES1-ETO-1000-01 PDF
Ethylene Oxide TB420-ES4-ETO 0 – 10 ppm ES4 04-TB420-ES4-ETO-10-01 PDF
Ethylene Oxide TB420-ES4-ETO 0 – 200 ppm ES4 04-TB420-ES4-ETO-200-01 PDF
Ethylene Oxide TB420-ES4-ETO 0 – 1000 ppm ES4 04-TB420-ES4-ETO-1000-01 PDF
Fluorine TB420-EC4-F2 0 – 5 ppm EC4 04-TB420-EC4-F2-5-01 PDF
Germane TB420-ES1-GeH4 0 – 5 ppm ES1 04-TB420-ES1-GeH4-5-01 PDF
Germane TB420-ES4-GeH4 0 – 5 ppm ES4 04-TB420-ES4-GeH4-5-01 PDF
Hydrogen TB420-ES1-H2 0 – 1000 ppm ES1 04-TB420-ES1-H2-1000-01 PDF
Hydrogen TB420-ES1-H2 0 – 5000 ppm ES1 04-TB420-ES1-H2-5000-01 PDF
Hydrogen TB420-ES1-H2 0 – 5 % vol. ES1 04-TB420-ES1-H2-5%-01 PDF
Hydrogen TB420-ES4-H2 0 – 1000 ppm ES4 04-TB420-ES4-H2-1000-01 PDF
Hydrogen TB420-ES4-H2 0 – 5000 ppm ES4 04-TB420-ES4-H2-5000-01 PDF
Hydrogen TB420-ES4-H2 0 – 5 % vol. ES4 04-TB420-ES4-H2-5%-01 PDF
Hydrogen Sulfide TB420-ES1-H2S 0 – 5 ppm ES1 04-TB420-ES1-H2S-5-01 PDF
Hydrogen Sulfide TB420-ES1-H2S 0 – 10 ppm ES1 04-TB420-ES1-H2S-10-01 PDF
Hydrogen Sulfide TB420-ES1-H2S 0 – 100 ppm ES1 04-TB420-ES1-H2S-100-01 PDF
Hydrogen Sulfide TB420-ES1-H2S 0 – 1000 ppm ES1 04-TB420-ES1-H2S-1000-01 PDF
Hydrogen Sulfide TB420-ES1-H2S 0 – 5000 ppm ES1 04-TB420-ES1-H2S-5000-01 PDF
Hydrogen Sulfide TB420-ES4-H2S 0 – 5 ppm ES4 04-TB420-ES4-H2S-5-01 PDF
Hydrogen Sulfide TB420-ES4-H2S 0 – 10 ppm ES4 04-TB420-ES4-H2S-10-01 PDF
Hydrogen Sulfide TB420-ES4-H2S 0 – 100 ppm ES4 04-TB420-ES4-H2S-100-01 PDF
Hydrogen Sulfide TB420-ES4-H2S 0 – 1000 ppm ES4 04-TB420-ES4-H2S-1000-01 PDF
Hydrogen Sulfide TB420-ES4-H2S 0 – 5000 ppm ES4 04-TB420-ES4-H2S-5000-01 PDF
Formaldehyde TB420-ES1-HCHO 0 – 5 ppm ES1 04-TB420-ES1-HCHO-5-01 PDF
Formaldehyde TB420-ES1-HCHO 0 – 100 ppm ES1 04-TB420-ES1-HCHO-100-01 PDF
Formaldehyde TB420-ES4-HCHO 0 – 5 ppm ES4 04-TB420-ES4-HCHO-5-01 PDF
Formaldehyde TB420-ES4-HCHO 0 – 100 ppm ES4 04-TB420-ES4-HCHO-100-01 PDF
Hydrogen Cyanide TB420-ES1-HCN 0 – 50 ppm ES1 04-TB420-ES1-HCN-50-01 PDF
Hydrogen Cyanide TB420-ES4-HCN 0 – 50 ppm ES4 04-TB420-ES4-HCN-50-01 PDF
Hydrogen Chloride TB420-EC4-HCl 0 – 30 ppm EC4 04-TB420-EC4-HCl-30-01 PDF
Hydrogen Fluoride TB420-EC4-HF 0 – 10 ppm EC4 04-TB420-EC4-HF-10-01 PDF
Ammonia TB420-EC4-NH3 0 – 100 ppm EC4 04-TB420-EC4-NH3-100-01 PDF
Ammonia TB420-EC4-NH3 0 – 500 ppm EC4 04-TB420-EC4-NH3-500-01 PDF
Ammonia TB420-EC4-NH3 0 – 1000 ppm EC4 04-TB420-EC4-NH3-1000-01 PDF
Ammonia TB420-ES1-NH3 0 – 10 ppm ES1 04-TB420-ES1-NH3-10-01 PDF
Ammonia TB420-ES1-NH3 0 – 100 ppm ES1 04-TB420-ES1-NH3-100-01 PDF
Ammonia TB420-ES4-NH3 0 – 10 ppm ES4 04-TB420-ES4-NH3-10-01 PDF
Ammonia TB420-ES4-NH3 0 – 100 ppm ES4 04-TB420-ES4-NH3-100-01 PDF
Nitrogen Dioxide TB420-ES1-NO2 0 – 5 ppm ES1 04-TB420-ES1-NO2-5-02 PDF
Nitrogen Dioxide TB420-ES1-NO2 0 – 50 ppm ES1 04-TB420-ES1-NO2-50-01 PDF
Nitrogen Dioxide TB420-ES1-NO2 0 – 100 ppm ES1 04-TB420-ES1-NO2-100-01 PDF
Nitrogen Dioxide TB420-ES1-NO2 0 – 1000 ppm ES1 04-TB420-ES1-NO2-1000-01 PDF
Nitrogen Dioxide TB420-ES1-NO2 0 – 2000 ppm ES1 04-TB420-ES1-NO2-2000-01 PDF
Nitrogen Dioxide TB420-ES4-NO2 0 – 5 ppm ES4 04-TB420-ES4-NO2-5-02 PDF
Nitrogen Dioxide TB420-ES4-NO2 0 – 50 ppm ES4 04-TB420-ES4-NO2-50-01 PDF
Nitrogen Dioxide TB420-ES4-NO2 0 – 100 ppm ES4 04-TB420-ES4-NO2-100-01 PDF
Nitrogen Dioxide TB420-ES4-NO2 0 – 1000 ppm ES4 04-TB420-ES4-NO2-1000-01 PDF
Nitrogen Dioxide TB420-ES4-NO2 0 – 2000 ppm ES4 04-TB420-ES4-NO2-2000-01 PDF
Oxygen TB420-ES1-O2 0 – 25 % vol. ES1 04-TB420-ES1-O2-25%-01 PDF
Oxygen TB420-ES4-O2 0 – 25 % vol. ES4 04-TB420-ES4-O2-25%-01 PDF
Ozone TB420-ES1-O3 0 – 5 ppm ES1 04-TB420-ES1-O3-5-01 PDF
Ozone TB420-ES1-O3 0 – 50 ppm ES1 04-TB420-ES1-O3-50-01 PDF
Ozone TB420-ES1-O3 0 – 100 ppm ES1 04-TB420-ES1-O3-100-01 PDF
Ozone TB420-ES4-O3 0 – 5 ppm ES4 04-TB420-ES4-O3-5-01 PDF
Ozone TB420-ES4-O3 0 – 50 ppm ES4 04-TB420-ES4-O3-50-01 PDF
Ozone TB420-ES4-O3 0 – 100 ppm ES4 04-TB420-ES4-O3-100-01 PDF
Phosphine TB420-ES1-PH3 0 – 5 ppm ES1 04-TB420-ES1-PH3-5-01 PDF
Phosphine TB420-ES1-PH3 0 – 20 ppm ES1 04-TB420-ES1-PH3-20-01 PDF
Phosphine TB420-ES1-PH3 0 – 100 ppm ES1 04-TB420-ES1-PH3-100-01 PDF
Phosphine TB420-ES1-PH3 0 – 2000 ppm ES1 04-TB420-ES1-PH3-2000-01 PDF
Phosphine TB420-ES4-PH3 0 – 5 ppm ES4 04-TB420-ES4-PH3-5-01 PDF
Phosphine TB420-ES4-PH3 0 – 20 ppm ES4 04-TB420-ES4-PH3-20-01 PDF
Phosphine TB420-ES4-PH3 0 – 100 ppm ES4 04-TB420-ES4-PH3-100-01 PDF
Phosphine TB420-ES4-PH3 0 – 2000 ppm ES4 04-TB420-ES4-PH3-2000-01 PDF
Odor & Smell TB420-ES1-SMELL 0 – 5 ppm ES1 04-TB420-ES1-SMELL-5-01 PDF
Odor & Smell TB420-ES1-SMELL 0 – 10 ppm ES1 04-TB420-ES1-SMELL-10-01 PDF
Odor & Smell TB420-ES1-SMELL 0 – 200 ppm ES1 04-TB420-ES1-SMELL-200-01 PDF
Odor & Smell TB420-ES1-SMELL 0 – 500 ppm ES1 04-TB420-ES1-SMELL-500-01 PDF
Odor & Smell TB420-ES4-SMELL 0 – 5 ppm ES4 04-TB420-ES4-SMELL-5-01 PDF
Odor & Smell TB420-ES4-SMELL 0 – 10 ppm ES4 04-TB420-ES4-SMELL-10-01 PDF
Odor & Smell TB420-ES4-SMELL 0 – 200 ppm ES4 04-TB420-ES4-SMELL-200-01 PDF
Odor & Smell TB420-ES4-SMELL 0 – 500 ppm ES4 04-TB420-ES4-SMELL-500-01 PDF
Sulfur Dioxide TB420-ES1-SO2 0 – 5 ppm ES1 04-TB420-ES1-SO2-5-01 PDF
Sulfur Dioxide TB420-ES1-SO2 0 – 50 ppm ES1 04-TB420-ES1-SO2-50-01 PDF
Sulfur Dioxide TB420-ES1-SO2 0 – 100 ppm ES1 04-TB420-ES1-SO2-100-01 PDF
Sulfur Dioxide TB420-ES1-SO2 0 – 1000 ppm ES1 04-TB420-ES1-SO2-1000-01 PDF
Sulfur Dioxide TB420-ES1-SO2 0 – 2000 ppm ES1 04-TB420-ES1-SO2-2000-01 PDF
Sulfur Dioxide TB420-ES4-SO2 0 – 5 ppm ES4 04-TB420-ES4-SO2-5-01 PDF
Sulfur Dioxide TB420-ES4-SO2 0 – 50 ppm ES4 04-TB420-ES4-SO2-50-01 PDF
Sulfur Dioxide TB420-ES4-SO2 0 – 100 ppm ES4 04-TB420-ES4-SO2-100-01 PDF
Sulfur Dioxide TB420-ES4-SO2 0 – 1000 ppm ES4 04-TB420-ES4-SO2-1000-01 PDF
Sulfur Dioxide TB420-ES4-SO2 0 – 2000 ppm ES4 04-TB420-ES4-SO2-2000-01 PDF
Silane TB420-ES1-SiH4 0 – 10 ppm ES1 04-TB420-ES1-SiH4-10-01 PDF
Silane TB420-ES4-SiH4 0 – 10 ppm ES4 04-TB420-ES4-SiH4-10-01 PDF
Volatile Organic Compounds (TVOC) TB420-ES1-TVOC 0 – 10 ppm ES1 04-TB420-ES1-TVOC-10-01 PDF
Volatile Organic Compounds (TVOC) TB420-ES1-TVOC 0 – 200 ppm ES1 04-TB420-ES1-TVOC-200-01 PDF
Volatile Organic Compounds (TVOC) TB420-ES1-TVOC 0 – 1000 ppm ES1 04-TB420-ES1-TVOC-1000-01 PDF
Volatile Organic Compounds (TVOC) TB420-ES1-TVOC 0 – 2000 ppm ES1 04-TB420-ES1-TVOC-2000-01 PDF
Volatile Organic Compounds (TVOC) TB420-ES4-TVOC 0 – 10 ppm ES4 04-TB420-ES4-TVOC-10-01 PDF
Volatile Organic Compounds (TVOC) TB420-ES4-TVOC 0 – 200 ppm ES4 04-TB420-ES4-TVOC-200-01 PDF
Volatile Organic Compounds (TVOC) TB420-ES4-TVOC 0 – 1000 ppm ES4 04-TB420-ES4-TVOC-1000-01 PDF
Volatile Organic Compounds (TVOC) TB420-ES4-TVOC 0 – 2000 ppm ES4 04-TB420-ES4-TVOC-2000-01 PDF

Frequently Asked Questions

Can it measure silane, diborane and germane? How do I choose?

Yes. These three semiconductor hydride specialty gases are available on the TB420 in both ES1 and ES4 cell versions: silane 0 – 10 ppm (0.001 ppm resolution), diborane 0 – 1 ppm (0.001 ppm) and germane 0 – 5 ppm (0.01 ppm), all with a two-wire 4–20 mA output. A practical selection order is to treat the gas as flammable first and then confirm leakage at ppm level: silane has an autoignition temperature of about 21 °C and is pyrophoric (NFPA 704 flammability 4), with a flammable range of 1.37% – 96% vol and a relative density of about 1.12, so leaks are slightly heavier than air and accumulate low, in trenches and valve boxes — mount detection points near the leak source and low, not only overhead. The official cross-sensitivity table also shows 100 ppm hydrogen reading about 20 ppm on the silane channel (roughly 20% positive interference) and 1 ppm chlorine reading negative (about −0.5 ppm); where hydrogen or chlorine is present, subtract at system level or use separate channels.

How do I choose between 4–20 mA and a digital interface?

It depends on where the data ends up. Choose 4–20 mA when the value feeds an analog input on a PLC or DCS, when cable runs span tens to hundreds of metres, or when VFDs and heavy equipment are nearby — a current loop is insensitive to cable resistance and anything below 4 mA is inherently an open-circuit alarm. Choose a UART / I²C digital module (the TB200B and TB600B&C series here) for custom instruments that need temperature and humidity alongside the reading, custom algorithms, or battery power. Running both is common: distant field points over 4–20 mA, in-device points over a digital interface.

How is the two-wire connection made, and what supply is needed?

Two-wire means supply and signal share the same conductor pair with the module in the loop: the positive side takes 9 – 24 V DC (24 V recommended) and the loop current varies between 3 and 22 mA with concentration. On a PLC analog input, scale 4 mA to the bottom of the range and 20 mA to the top; a reading below 4 mA indicates an open circuit or fault, and a dedicated fault output pin can drive an alarm circuit. Total consumption is under 0.6 W. A higher supply voltage allows longer cable runs and more loop headroom.

Can it be used for %LEL combustible-gas alarms?

It does not replace a %LEL alarm, and this point matters. The TB420 is a ppm-level toxic and harmful gas module whose ranges and resolution are designed around occupational exposure limits and leak detection. The carbon monoxide 0 – 2% vol and oxygen 0 – 25% vol spans in the catalogue are extensions for high-concentration duty and oxygen deficiency or enrichment monitoring, not combustible-gas lower-explosive-limit alarms. For %LEL alarms, choose a catalytic bead or infrared combustible-gas sensor.

What are the accuracy, lifetime and warranty?

Accuracy is ±5% of the measured value with repeatability better than 2% and a linear output; expected lifetime exceeds 5 years, and a sensor lifetime self-test helps schedule replacement ahead of time. Warranty is 12 months from the date of shipment. Exact figures are stated in the official datasheet for each model, downloadable from its product page.

How do I get a quote, samples and datasheets?

Every datasheet is downloadable from its product page on this site. For samples and volume pricing, send us the target gas, range, cell option (ES1/ES4/EC4), the number of measuring points and annual volume through the contact form or by email, and we will quote the matching model and order number with lead time.

Need Help Choosing a Model?

Send us your target gas, range, system architecture and point count — we will match the model and quote it. Datasheets for all 25 gas types and 47 models are available to download now.