| What It Measures | Ppm-level toxic gases (CO, H₂S, O₂, NH₃, O₃, TVOC and 11 more) | Total combustible gas (%LEL) | IR-active gases: methane, CO₂, SF₆ and similar | Reducing gases (ethanol, VOCs, some combustibles) |
| Resolution & Lower Limit | Down to 0.01 ppm (TVOC-10); 0.1 – 1 ppm typical | %LEL scale, typically 1% LEL | ppm to %VOL, depending on path length | Ppm level, with substantial baseline drift |
| Selectivity | High — electrode chemistry and bias optimised per target gas | Low — one total combustible figure | High, but limited to IR-active gases | Low, with pronounced cross-sensitivity |
| Response Time | < 3 s (T90 30 – 130 s, gas dependent) | 10 – 30 s | 1 – 10 min | Seconds to tens of seconds |
| Power Draw | ≤ 5 mW @ 5 V; 0.35 mA in sleep | High — heated catalytic bead | Medium to high — IR source required | Medium to high — heated element |
| Lifetime & Maintenance | > 3 years, no consumables; offline secondary calibration supported | 2 – 5 years, periodic calibration; prone to silicone poisoning | 5 – 10 years, optical cell must stay clean | Shorter life; drift requires frequent correction |
| Typical Applications | Industrial safety, leak detection, portable and battery-powered devices, IoT nodes | Combustible gas alarms (%LEL), gas and petrochemical sites | Gas networks, biogas, greenhouse-gas online monitoring | Low-cost consumer alarms and trend monitoring |